The PEL 102 is a low cost, simple to use, one, two (split phase) and three phase (Wye and Delta) power/energy data logger. This product is ideal for electricians, engineers and contractors doing work in the area of building and system monitoring and upgrades, as well as residential and overall energy audits. All vital energy data is easily measured, recorded, and analyzed. Reports can be generated with confidence with minimal configuration time and effort (Standard and Customizable Reports supplied).
The instrument’s design enables it to be installed inside a load center panel (including the current sensors) and still allow the door to close on most panels. The PEL 100 series offers all the essential functions for logging power/energy data from most electrical power networks in use today across the world (17 network set-ups provided). The PEL 100 series energy loggers measure and record three voltage inputs and current inputs, Watts, VARS, VA and Energy (kWh and kVA). Power Factor (PF), Displacement Power Factor (DPF), Crest Factor, Frequency and THD are calculated and recorded as well. Individual harmonic % information from 1 to the 50th harmonic are recorded at the operator’s choice. All variables are recorded and stored at a one second interval and on user selectable demand intervals from 1 to 60 minutes.
Energy costs can be calculated and displayed quickly and easily by simply inputting the unit cost for a kilowatt hour into the software. Data is stored on a removable SD card. Data can be retrieved using a USB, Bluetooth and/or Ethernet (local or internet) connection by transporting the SD card back to a PC. The comprehensive DataView® software (included) provides the ability to view data from several hundred PEL 100 series instruments on a local network or over the internet allowing the user to evaluate energy usage in a department or facility basis, a remote site, or even in a city, anywhere in the world. DataView® allows measurements to be viewed in real-time on a PC and stored data to be downloaded for analysis and report generation.
Features:
- Measurement of RMS voltages and currents at 128 times per cycle and stored every second
- Measurement of VA, W and var power values (total and per phase) stored every second
- Measurement of VAh, Wh and varh energy values (total and per phase) per second with source/load indication
- Calculation of the cos f Displacement Power Factor (DPF) and the Power Factor (PF) stored every second
- Calculation of Total Harmonic Distortion (THD)
- Measurement, calculation and display of the harmonics up to the 50th order for 50/60 Hz and 7th order for 400Hz
- Measurement of the DC quantities (RMS calculation)
- Electrical network quantities are stored on a removable SD-Card
- Automatic recognition of the connected current sensors
- DataView software for configuration, data retrieval and real-time viewing of measurements with a PC
- Compact and rugged case
- Versatile communication interface choices built in (USB, Ethernet, Bluetooth)
Applications:
- Measure efficiency, find areas for potential savings
- Track Sub-billing occupants for energy costs
- Assign energy costs to departments or operations within a department
- Track peak demand periods and find opportunities for surcharge reductions
- Determine present capacity and circumvent unnecessary electrical expansion costs
- Verify the reliability and operation of electrical machinery
- Improve response time to solve power related problems
- Track energy availability and reliability of supply
- Reduce field service time at sub-stations
Returns Refunds And Warranty Claims
Please note that although we make every effort to keep our refund returns and warranty policies current, the Testrix Systems return refund and warranties policy as shown below may be subject to change over time. Please contact us to discuss your return or refund. Because of the nature of our equipment, we do not offer change of mind refunds.
Refunds And Returns Terms And Conditions Overview
- Our policy lasts 14 days.
- If 14 days have gone by since your purchase, unfortunately we can’t offer you a refund or exchange.
- To be eligible for a return, your item must be unused and in the same condition that you received it. It must also be in the original packaging.
- Most of our equipment is exempt from being returned, because it may be very specialized and customized to your specific needs.
- We only replace items if they are defective or damaged. If you need to exchange it for the same item, send us an email at sales@testrix.com.au.
Send your item to:
Lvl 19, 10 Eagle Street, Brisbane, QLD 4000. Please do not send any equipment to use without obtaining prior approval and a valid RMA number.
Partial Refunds
There are certain situations where only partial refunds are granted (if applicable) on returned products:
- Equipment with obvious signs of use
- Any part of the equipment that has been opened.
- Any item not in its original condition, is damaged or missing parts for reasons not due to our error.
- Any item that is returned more than 30 days after delivery
- Any equipment being returned for reasons other than a warranty claim
- If Testrix Systems accepts equipment for return within 14 days at it's discretion, a re-stocking fee of 30% will be levied against any refund amount.
Warranty Claims
As the manufacturer, we warrant all of our equipment against faulty workmanship and defects and as such we will repair or replace any equipment which is faulty as a result of our manufacturing processes. For any equipment not manufactured by Testrix Systems, we will undertake all necessary obligations or duties with the original equipment manufacturer (OEM) on your behalf to process any warranty claim on your behalf.
Should you wish to commence a warranty claim, please email us at sales@testrix.com.au and request a Returns Material Authorisation (RMA) form. We will ask you to explain the nature of the claim and if applicable, issue you with a returns number.
Void Warranties
There are some situations where a warranty claim cannot be granted:
- Equipment with any physical damage.
- Any part of the equipment which has been tampered with. This includes opening the equipment (apart from the battery cover) without prior authorisation.
- Any equipment with missing parts or components, replacement or non-standard parts.
- Any piece of equipment which may shows signs of misuse.
- Any equipment which is not deemed to be faulty when examined.
- In the case of pipe inspection camera systems, water damage or ingress to camera heads.
You will be responsible for paying your own shipping costs for returning the equipment. Shipping costs are non-refundable. If we grant a warranty claim, we will bear the return shipping costs to you.
A decision to grant or refuse a warranty claim is at the complete discretion of Testrix Systems. Should a warranty claim be refused, we may also charge an inspection fee, and return shipping to you.
Australian Purchases
The following statement applies only to Australian purchases:
- Our goods come with guarantees that cannot be excluded under the Australian Consumer Law.
- You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage.
- You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.
Shipping Returns
To return your product, you should send your product to:
Lvl 19, 10 Eagle Street, Brisbane, QLD 4000. Please only send items once you have a valid RMA number and NOT before.
You will be responsible for paying for your own shipping costs for returning your item. Shipping costs are non-refundable. If you receive a refund, the cost of return shipping will be deducted from your refund.
Acceptance Of Returns
We are unable to accept returns for any other purpose other than warranty claims.
We also do not accept products that have been removed from their original packaging, or that show any signs of use.
The decision to accept a return, other than a warranty claim is at the complete discretion of Testrix Systems.
Important, please note:
- In the event of accepting a return, in order to complete it, we require a copy of the original tax invoice or proof of purchase.
- Please do not send any equipment to us without a completed Returns Material Authorisation (RMA) form, which must first be approved by Testrix Systems.
- On approval, we will issue you with a returns number. Without this number, we cannot accept any equipment at our premises.
Returns And Refunds Processing (if applicable)
Once your return is received and inspected, we will send you an email to notify you that we have received your returned item. We will also notify you of the approval or rejection of your refund.
Please note: The granting of a refund is at the complete discretion of Testrix Systems and is non-negotiable. We also reserve the right to deduct a re-stocking fee of 30% of the original invoice value.
If you are approved, then your refund (minus any re-stocking fee) will be processed, and a credit will automatically be applied to your credit card or original method of payment, within a reasonable time frame, usually no longer than 7 days in most cases.
Late or missing refunds (if applicable)
- If you haven’t received a refund within 7 days, first check your bank account.
- Then contact your credit card company, it may take some time before your refund is officially posted.
- Next contact your bank. There is often some processing time before a refund is posted.
- If you’ve done all of this and you still have not received your refund yet, please contact us at sales@testrix.com.au.
Exchanges (if applicable)
- Depending on where you live, the time it may take for your exchanged product to reach you may vary.
- If you are shipping an item over $75, you should consider using a trackable shipping service or purchasing shipping insurance, as we can’t guarantee that we will receive your returned item.
More From This Category