Advanced 3-Phase Power Quality Analysis with Precision, Flexibility, and Full Compliance

The AEMC 8345 PowerPad® IV Class A Power Quality Analyser is a high-performance, feature-rich, and fully compliant 3-phase portable power quality analyser designed for professionals who require top-tier measurement accuracy and real-time diagnostic capabilities. With Class A compliance per IEC 61000-4-30 Edition 3, built-in GPS for precise time synchronisation, and advanced trending, logging, and harmonics analysis, the AEMC 8345 is a powerhouse tool for energy professionals, electrical engineers, and utility technicians.

Whether you are troubleshooting power issues, validating system performance, or conducting long-term power quality studies, the AEMC 8345 provides the ultimate combination of portability, accuracy, and functionality in the field.

Key Features of the AEMC 8345 PowerPad IV

Full IEC 61000-4-30 Class A Compliance (Edition 3)
Guarantees highly accurate, reproducible, and standardised power quality measurements for professional analysis, reporting, and compliance verification.

Built-in GPS Time Synchronisation
Automatically aligns recorded data with global time standards for precise event correlation and report generation—especially critical in multi-site studies.

Simultaneous Multi-Parameter Data Logging
Records all parameters without compromise, including voltage, current, frequency, harmonics, transients, inrush, and more—with 1ms time stamping.

High-Speed Transient Detection
Captures waveform anomalies with an extremely fast sample rate for pinpointing events like surges, impulses, or switching noise.

Harmonics and Interharmonics (up to 127th order)
Advanced spectral analysis with THD, individual harmonic magnitudes, and phase angles helps diagnose distortion and resonance issues.

5 Voltage & 4 Current Channels
Supports single-phase, split-phase, and 3-phase (wye or delta) systems with full four current input monitoring for complete electrical network analysis.

Large 7” Colour Touchscreen Display
Intuitive interface with real-time waveforms, phasor diagrams, and visual alerts for threshold exceedance or anomaly detection.

Internal Memory + Removable SD Card
Massive logging capacity suitable for extended monitoring campaigns without data loss or compression.

Flexible Sensor Compatibility
Works with a wide range of current sensors including AC, DC, and Rogowski coils to suit different measurement environments and conductor sizes.

Remote Configuration and Download via DataView® Software
Powerful software suite for in-depth analysis, customised reporting, and remote control over Ethernet or USB.

Comprehensive Measurement Capabilities

The AEMC 8345 goes far beyond basic voltage and current monitoring. It provides:

  Parameter

  Description

  RMS Voltage and Current

  Real-time and logged values for each phase and neutral

  Frequency (42.5-69Hz)

  Monitors fluctuations and instabilities

  Power (kW, kVA, kVAR)

  Active, reactive, and apparent power

  Power Factor / Displacement PF

  Energy efficiency indicators

  Harmonic Analysis

  Up to the 127th harmonic with graphical trends

  Unbalance & Flicker

  Key indicators for system instability

  Transients

  Captures events as brief as 0.5µs

  Inrush Currents

  Essential for motor startup analysis

  Energy (kWh, kVARh)

  Tracks energy usage over time

  Event Recording & Alarm Logging

  Logs sags, swells, interruptions, over/under voltage events

Applications

  • Facility and Building Diagnostics
    Identify sources of power disturbances, optimise energy usage, and validate power conditioning equipment performance.
  • Industrial Equipment Troubleshooting
    Detect harmonics, voltage dips, or transients affecting sensitive machinery and VFDs.
  • Utility and Power Distribution Monitoring
    Ensure compliance with utility power quality standards, analyse feeder loads, and verify substation stability.
  • Energy Audits and Cost Reduction Studies
    Analyse energy consumption trends, identify wastage, and justify power factor correction or demand-side management.
  • Commissioning and System Validation
    Evaluate new installations to ensure they meet operational and regulatory benchmarks.

What’s Included

  • AEMC 8345 PowerPad IV Analszer Unit
  • Voltage leads and colour-coded alligator clips
  • Soft carry case
  • USB cable and Ethernet cable
  • GPS antenna for precise synchronization
  • SD card (16GB supplied)
  • Rechargeable battery and AC adapter
  • DataView® Software CD or download link
  • User manual and calibration certificate

Technical Specifications (Snapshot)

  Specification

  Value

  Input Voltage Range

  1000V CAT IV

  Current Measurement

  Up to 10,000A (sensor dependent)

  Sampling Rate

  Voltage 400 kSps / Current 200 kSps / Surge 2 MSps

  Memory Capacity

  Internal + SD (up to 32GB)

  Battery Life

  Up to 8 hours (rechargeable)

  Display

  7” color TFT touchscreen

  Interfaces

  USB, Ethernet, Wi-Fi, Web server, DataViewSync™, USB

  Dimensions

  285 x 200 x 55 mm

  Weight

  Approx. 1.9kg

Why Choose the AEMC 8345 PowerPad® IV?

The AEMC 8345 stands out in the power quality instrumentation market for its unrivaled measurement accuracy, robust construction, and intelligent diagnostic features. As a true Class A power quality analyzer, it is trusted by engineers across sectors for regulatory compliance, in-depth fault finding, and precision monitoring in mission-critical systems.

Its built-in GPS synchronisation, high-speed transient recording, and seamless integration with DataView® software ensure you’re always one step ahead in diagnosing and solving power quality challenges.

Order the AEMC 8345 Power Quality Analyser Today

Upgrade your electrical diagnostic capabilities with the AEMC 8345 PowerPad IV. Whether you are performing routine maintenance, tackling complex power quality issues, or documenting power disturbances for compliance, this analyser delivers the performance and reliability professionals demand.

Available now from Testrix Systems, an authorised AEMC distributor and service agent. Request a quote or contact us today for expert advice and availability.

Returns Refunds And Warranty Claims

Please note that although we make every effort to keep our refund returns and warranty policies current, the Testrix Systems return refund and warranties policy as shown below may be subject to change over time. Please contact us to discuss your return or refund. Because of the nature of our equipment, we do not offer change of mind refunds.

Refunds And Returns Terms And Conditions Overview

  • Our policy lasts 14 days.
  • If 14 days have gone by since your purchase, unfortunately we can’t offer you a refund or exchange.
  • To be eligible for a return, your item must be unused and in the same condition that you received it. It must also be in the original packaging.
  • Most of our equipment is exempt from being returned, because it may be very specialized and customized to your specific needs.
  • We only replace items if they are defective or damaged.  If you need to exchange it for the same item, send us an email at sales@testrix.com.au.

Send your item to:

Lvl 19, 10 Eagle Street, Brisbane, QLD 4000. Please do not send any equipment to use without obtaining prior approval and a valid RMA number.

Partial Refunds

There are certain situations where only partial refunds are granted (if applicable) on returned products:

  • Equipment with obvious signs of use
  • Any part of the equipment that has been opened.
  • Any item not in its original condition, is damaged or missing parts for reasons not due to our error.
  • Any item that is returned more than 30 days after delivery
  • Any equipment being returned for reasons other than a warranty claim
  • If Testrix Systems accepts equipment for return within 14 days at it's discretion, a re-stocking fee of 30% will be levied against any refund amount.

Warranty Claims

As the manufacturer, we warrant all of our equipment against faulty workmanship and defects and as such we will repair or replace any equipment which is faulty as a result of our manufacturing processes. For any equipment not manufactured by Testrix Systems, we will undertake all necessary obligations or duties with the original equipment manufacturer (OEM) on your behalf to process any warranty claim on your behalf.

Should you wish to commence a warranty claim, please email us at sales@testrix.com.au and request a Returns Material Authorisation (RMA) form. We will ask you to explain the nature of the claim and if applicable, issue you with a returns number.

Void Warranties

There are some situations where a warranty claim cannot be granted:

  • Equipment with any physical damage.
  • Any part of the equipment which has been tampered with. This includes opening the equipment (apart from the battery cover) without prior authorisation.
  • Any equipment with missing parts or components, replacement or non-standard parts.
  • Any piece of equipment which may shows signs of misuse.
  • Any equipment which is not deemed to be faulty when examined.
  • In the case of pipe inspection camera systems, water damage or ingress to camera heads.

You will be responsible for paying your own shipping costs for returning the equipment. Shipping costs are non-refundable. If we grant a warranty claim, we will bear the return shipping costs to you.

A decision to grant or refuse a warranty claim is at the complete discretion of Testrix Systems. Should a warranty claim be refused, we may also charge an inspection fee, and return shipping to you.

Australian Purchases

The following statement applies only to Australian purchases:

  • Our goods come with guarantees that cannot be excluded under the Australian Consumer Law.
  • You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage.
  • You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.

Shipping Returns

To return your product, you should send your product to:

Lvl 19, 10 Eagle Street, Brisbane, QLD 4000. Please only send items once you have a valid RMA number and NOT before.

You will be responsible for paying for your own shipping costs for returning your item. Shipping costs are non-refundable. If you receive a refund, the cost of return shipping will be deducted from your refund.

Acceptance Of Returns

We are unable to accept returns for any other purpose other than warranty claims.

We also do not accept products that have been removed from their original packaging, or that show any signs of use.

The decision to accept a return, other than a warranty claim is at the complete discretion of Testrix Systems.

Important, please note:

  • In the event of accepting a return, in order to complete it, we require a copy of the original tax invoice or proof of purchase.
  • Please do not send any equipment to us without a completed Returns Material Authorisation (RMA) form, which must first be approved by Testrix Systems.
  • On approval, we will issue you with a returns number. Without this number, we cannot accept any equipment at our premises.

Returns And Refunds Processing (if applicable)

Once your return is received and inspected, we will send you an email to notify you that we have received your returned item. We will also notify you of the approval or rejection of your refund.

Please note: The granting of a refund is at the complete discretion of Testrix Systems and is non-negotiable. We also reserve the right to deduct a re-stocking fee of 30% of the original invoice value.

If you are approved, then your refund (minus any re-stocking fee) will be processed, and a credit will automatically be applied to your credit card or original method of payment, within a reasonable time frame, usually no longer than 7 days in most cases.

Late or missing refunds (if applicable)

  • If you haven’t received a refund within 7 days, first check your bank account.
  • Then contact your credit card company, it may take some time before your refund is officially posted.
  • Next contact your bank. There is often some processing time before a refund is posted.
  • If you’ve done all of this and you still have not received your refund yet, please contact us at sales@testrix.com.au.

Exchanges (if applicable)

  • Depending on where you live, the time it may take for your exchanged product to reach you may vary.
  • If you are shipping an item over $75, you should consider using a trackable shipping service or purchasing shipping insurance, as we can’t guarantee that we will receive your returned item.