Overview

The HIKMICRO B20S is a powerful, professional-grade infrared thermal imaging camera engineered for electrical, mechanical, building, and HVAC diagnostics. Offering crisp thermal images, a wide temperature measurement range, and integrated visual imaging, the B20S is built to identify faults, prevent downtime, and enhance safety across a range of industrial and commercial applications.

Designed with field usability in mind, the B20S combines high thermal sensitivity, rugged construction, and smart features in a compact, handheld design. Whether you’re detecting heat loss, overloaded circuits, or mechanical friction, this camera delivers reliable insights with speed and precision.

Key Features of the HIKMICRO B20S

1. High-Resolution Thermal Sensor

  • 256 × 192 IR resolution (49,152 pixels)
  • Provides clear and detailed thermal images to accurately detect small temperature anomalies.

2. Visible Light Camera & Image Fusion

  • Integrated optical camera (2 MP) for dual-spectrum imaging
  • Supports thermal, visual, and fusion modes (including picture-in-picture) for better situational awareness and documentation.

3. Wide Temperature Measurement Range

  • -20°C to +550°C
  • Ideal for applications ranging from residential inspections to industrial maintenance and high-voltage equipment monitoring.

4. Superior Thermal Sensitivity

  • NETD < 40 mK
  • Detects even the slightest differences in temperature for precise diagnostics and early fault detection.

5. Super IR for Enhanced Thermal Clarity

  • HIKMICRO's SuperIR image enhancement technology upscales the resolution of captured thermal images to 640 x 480 (307,200 pixels)
  • Significantly improves thermal image quality. It also provides a smooth 25 Hz image frequency for live viewing and photo capture

6. Intuitive 3.2” LCD Touchscreen Display

  • High-brightness 640 × 480 LCD
  • Touch interface makes navigation fast and easy, even while wearing gloves.

7. Professional Analysis Tools

  • Supports multiple spot measurements, area boxes, and isotherms
  • Analyze thermal data in real-time to make informed decisions on-site.

8. Voice & Text Annotations

  • Easily document inspections with voice notes and onscreen text comments
  • Enhances report quality and reduces the chance of miscommunication or oversight.

9. Rugged and Field-Ready Design

  • IP54-rated housing protects against dust and water splashes
  • Drop-tested to 2 meters for reliable performance in harsh environments.

10. Long Battery Life & Fast Charging

  • Up to 6 hours continuous operation
  • Rechargeable Li-ion battery with Type-C fast charging support ensures minimal downtime.

11. HIKMICRO Analyzer Software Compatibility

  • Export and analyze thermal images using the free HIKMICRO Analyzer desktop software
  • Create comprehensive inspection reports with image comparison, annotations, and trend analysis.

12. Wi-Fi Connectivity

  • Connect to mobile devices via built-in Wi-Fi and the HIKMICRO Viewer App to quickly share your images.

Technical Specifications

  Feature

  Specification

  Thermal Resolution

  256 × 192 pixels

  Thermal Sensitivity (NETD)

  < 40 mK (@25°C, F#1.0)

  Temperature Range

  -20°C to +550°C (-4°F to +1022°F)

  Accuracy

  Max. (±2°C or ±2% of reading)

  Frame Rate

  25 Hz

  Field of View (FOV)

  50° × 37.2°

  Minimum Focus Distance

  0.3 m (thermal), 0.5 m (visual)

  Display

  3.2” LCD (640 × 480 resolution)

  Image Modes

  Thermal, Visual, Fusion, PIP

  Storage

  16GB eMMC internal memory (up to 35,000 images)

  Battery Life

  Approx. 6 hours

  Protection Rating

  IP54, 2 m drop tested

  Weight

  ~380 g

  Dimensions

  221.7 mm × 73.5 mm × 123.8 mm

Ideal Applications

  • Electrical inspections: Detect loose connections, overloaded circuits, and phase imbalances
  • Mechanical diagnostics: Monitor motor bearings, pumps, and gearboxes for overheating
  • Building inspections: Identify insulation defects, air leaks, and moisture intrusion
  • HVAC & plumbing: Evaluate system performance, duct leaks, and pipe blockages
  • Preventative maintenance: Locate hotspots before failure and reduce unplanned downtime

Why Choose the HIKMICRO B20S?

With the HIKMICRO B20S, professionals gain access to a reliable, high-performance thermal camera at a competitive price point. Its robust imaging capabilities, intuitive interface, and smart measurement tools make it the go-to choice for electricians, building inspectors, maintenance teams, and engineers seeking dependable thermal insight.

Returns Refunds And Warranty Claims

Please note that although we make every effort to keep our refund returns and warranty policies current, the Testrix Systems return refund and warranties policy as shown below may be subject to change over time. Please contact us to discuss your return or refund. Because of the nature of our equipment, we do not offer change of mind refunds.

Refunds And Returns Terms And Conditions Overview

  • Our policy lasts 14 days.
  • If 14 days have gone by since your purchase, unfortunately we can’t offer you a refund or exchange.
  • To be eligible for a return, your item must be unused and in the same condition that you received it. It must also be in the original packaging.
  • Most of our equipment is exempt from being returned, because it may be very specialized and customized to your specific needs.
  • We only replace items if they are defective or damaged.  If you need to exchange it for the same item, send us an email at sales@testrix.com.au.

Send your item to:

Lvl 19, 10 Eagle Street, Brisbane, QLD 4000. Please do not send any equipment to use without obtaining prior approval and a valid RMA number.

Partial Refunds

There are certain situations where only partial refunds are granted (if applicable) on returned products:

  • Equipment with obvious signs of use
  • Any part of the equipment that has been opened.
  • Any item not in its original condition, is damaged or missing parts for reasons not due to our error.
  • Any item that is returned more than 30 days after delivery
  • Any equipment being returned for reasons other than a warranty claim
  • If Testrix Systems accepts equipment for return within 14 days at it's discretion, a re-stocking fee of 30% will be levied against any refund amount.

Warranty Claims

As the manufacturer, we warrant all of our equipment against faulty workmanship and defects and as such we will repair or replace any equipment which is faulty as a result of our manufacturing processes. For any equipment not manufactured by Testrix Systems, we will undertake all necessary obligations or duties with the original equipment manufacturer (OEM) on your behalf to process any warranty claim on your behalf.

Should you wish to commence a warranty claim, please email us at sales@testrix.com.au and request a Returns Material Authorisation (RMA) form. We will ask you to explain the nature of the claim and if applicable, issue you with a returns number.

Void Warranties

There are some situations where a warranty claim cannot be granted:

  • Equipment with any physical damage.
  • Any part of the equipment which has been tampered with. This includes opening the equipment (apart from the battery cover) without prior authorisation.
  • Any equipment with missing parts or components, replacement or non-standard parts.
  • Any piece of equipment which may shows signs of misuse.
  • Any equipment which is not deemed to be faulty when examined.
  • In the case of pipe inspection camera systems, water damage or ingress to camera heads.

You will be responsible for paying your own shipping costs for returning the equipment. Shipping costs are non-refundable. If we grant a warranty claim, we will bear the return shipping costs to you.

A decision to grant or refuse a warranty claim is at the complete discretion of Testrix Systems. Should a warranty claim be refused, we may also charge an inspection fee, and return shipping to you.

Australian Purchases

The following statement applies only to Australian purchases:

  • Our goods come with guarantees that cannot be excluded under the Australian Consumer Law.
  • You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage.
  • You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.

Shipping Returns

To return your product, you should send your product to:

Lvl 19, 10 Eagle Street, Brisbane, QLD 4000. Please only send items once you have a valid RMA number and NOT before.

You will be responsible for paying for your own shipping costs for returning your item. Shipping costs are non-refundable. If you receive a refund, the cost of return shipping will be deducted from your refund.

Acceptance Of Returns

We are unable to accept returns for any other purpose other than warranty claims.

We also do not accept products that have been removed from their original packaging, or that show any signs of use.

The decision to accept a return, other than a warranty claim is at the complete discretion of Testrix Systems.

Important, please note:

  • In the event of accepting a return, in order to complete it, we require a copy of the original tax invoice or proof of purchase.
  • Please do not send any equipment to us without a completed Returns Material Authorisation (RMA) form, which must first be approved by Testrix Systems.
  • On approval, we will issue you with a returns number. Without this number, we cannot accept any equipment at our premises.

Returns And Refunds Processing (if applicable)

Once your return is received and inspected, we will send you an email to notify you that we have received your returned item. We will also notify you of the approval or rejection of your refund.

Please note: The granting of a refund is at the complete discretion of Testrix Systems and is non-negotiable. We also reserve the right to deduct a re-stocking fee of 30% of the original invoice value.

If you are approved, then your refund (minus any re-stocking fee) will be processed, and a credit will automatically be applied to your credit card or original method of payment, within a reasonable time frame, usually no longer than 7 days in most cases.

Late or missing refunds (if applicable)

  • If you haven’t received a refund within 7 days, first check your bank account.
  • Then contact your credit card company, it may take some time before your refund is officially posted.
  • Next contact your bank. There is often some processing time before a refund is posted.
  • If you’ve done all of this and you still have not received your refund yet, please contact us at sales@testrix.com.au.

Exchanges (if applicable)

  • Depending on where you live, the time it may take for your exchanged product to reach you may vary.
  • If you are shipping an item over $75, you should consider using a trackable shipping service or purchasing shipping insurance, as we can’t guarantee that we will receive your returned item.